This is a metal pipe that attaches to the pellet stove at one end typically with a pellet stove pipe chimney adapter and extends all the way through the chimney and above the roof at a suitable clearance.
Stove flue pipe installation.
Measure the distance from the wood burning stove flue collar to the collar on the insulated chimney using a measuring tape.
You re now ready to cut the stove pipe sections to length.
The minimum installation clearances for certified double wall flue pipes are much less than those for single wall pipes.
Of duraplus chimney pipe sold separately and features the necessary.
This one is the sealed type.
Wood stoves can get very very hot during use.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
Once you have the measurements for the pipe to fit accurately cut and slide into place.
Follow manufacturer recommendations whenever applicable.
Download our chimney pipe installation guide or build your chimney pipe using our automated chimney pipe builder.
A single wall stovepipe requires more clearance than a double walled stovepipe.
Installing a pellet stove pipe in an existing chimney requires a chimney liner.
A straight up double wall flue pipe assembly.
Determine the inner diameter of your chimney.
This through the wall chimney stove vent kit supports up to 40 ft.
In this video i will show you how to properly install a chimney pipe and explain why.
Install the pipes for a wood stove carefully.
The stovepipe connects the stove to a chimney pipe which extends through the roof.
There are two general types of double wall flue pipes.
Observe your stove s clearance rating when picking a suitable spot.
When a flue pipe travels farther than 3 m 10 feet to reach the insulated chimney break the amount of pipe into sections.
Radiating heat from the stove can pose a hazard to nearby walls and furniture so wood stoves generally have a specified clearance a minimum safe distance between the stove and nearby floors and walls.
Your stove clearance can depend on where you live whether your residence s.
Kevinrobinson6688 installchimneypipe chimneypipe selkirk dsp8tl 8 t.
The duraplus system from duravent is designed to the duraplus system from duravent is designed to stay cool on the outside provide a hot draft on the inside and boost stove efficiency offering a fire safe design that protects both the chimney and building.
This is usually the same size as the flue collar on your appliance.